Skip to main content

Table 2 External and internal heat transfer resistances of the building components and ground surfaces used within the one-dimensional model calculations (Maiullari et al. 2018)

From: Simulation of urban microclimate with uhiSolver: software validation using simplified material data

Component

Day

Night

Rse [W/(m2K)]

Rsi [W/(m2K)]

Rse [W/(m2K)]

Rsi [W/(m2K)]

External wall

0.04

0.13

0.04

0.13

Pitched roof

0.04

0.17

0.04

0.10

Flat roof

0.13

0.17

0.13

0.10

Ground surface

0.04

0.00

0.04

0.00