Skip to main content

Table 3 Calculation parameters of the five building types used within the one-dimensional model calculations

From: Simulation of urban microclimate with uhiSolver: software validation using simplified material data

Building type

Construction method

Room height (m)

Staircase material

Roof

Albedo

Roof

Façade

Type G1

Gründerzeit building

3.6

Stone

Pitched roof

0.225

0.7

Type G2

Concrete building 1970s

2.6

Concrete

Pitched roof

0.225

0.7

Type G3

Brick building 1970s

2.6

Concrete

Pitched roof

0.225

0.7

Type G4

New concrete building

2.6

Concrete

Flat roof

0.13

0.7

Type G5

New brick building

2.6

Concrete

Flat roof

0.13

0.7